• Emailhsdq@188.com
      • Phone0571-82699352
      • 中文
      Menu
      • Home
      • Products
        • Low-voltage distribution
        • Medium voltage distribution
        • Industrial control and protection
        • New energy
        • Complete sets of equipment
      • Download
        • Product sample
        • Manual of the modeling
        • Instruction book
        • Communication protocol
      • About Us
        • Brief introduction
        • “Hangshen” image
        • Technological innovation
        • Technical quality
        • Enterprise reputations
        • Enterprise culture
      • Contact Us

      Products

      Home>>HSL2 Series Residual Current Circuit Breaker
      • Industrial control and protection
        • control and protection switch
        • series thermal overload Relay
        • AC contactor
        • motor protector
      • New energy
      • Complete sets of equipment
        • Prefabricated substation
        • Low Voltage Complete-set Switchgear Equipment
        • High Voltage Complete-set Switchgear Equipment
      • Low-voltage distribution
        • Switch Disconnector
        • End Terminal Appliances
        • surge protector
        • automatic transfer switch automatic switch
        • Intelligent instrument
        • Intelligent Type Air Circuit Breaker
        • Moulded Case Circuit Breaker
          • Residual Current Circuit Breaker
          • Thermal Magnetic Moulded Case Circuit Breaker
          • Intelligent Type Moulded Case Circuit Breaker
      • Medium voltage distribution
        • Vacuum circuit breaker
      • Email hsdq@188.com
        • Technical 0571-82699110
        • Sales 0571-82699109
        • Service 0571-82600655

      HSL2 Series Residual Current Circuit Breaker

      Description

      HSL2 series Residual Current Circuit Breaker is competently applied in AC 50Hz electrical circuit with rated insulation voltage 690V, rated voltage 400V and rated current 16A~ 630A for electric shock and leakage protection, also can prevent fire danger caused by earth fault because of the insulation of the equipment damage. The circuit breaker can also be used as a circuit and the motor (400A and below) of the frequency division (conversion), when the line or motor overload, short circuit and other faults, can automatically protect and cut off the circuit.

      DownloadHSL2 Series Residual Current Circuit Breaker
      Tags
      • Low voltage distribution
      • Product Detail
      • Parameters

      The series circuit breakers possesses four rated frames: 100A、250A、400A、630A, the current specification 10A ~ 630A.

      • All series circuit breaker can be installed horizontally (lateral), vertical (vertical) and horizontal installation;
      • Whole series of breaker with isolation function
      • The circuit breaker meet the use requirements of installation site with the altitude not exceeding 2000 meters above sea level
      • The breaker can be divided into Electricity and motor protection by purpose.
      • Working conditions

      The surrounding medium temperature ranging from -5℃ to +40℃, average value within 24 hours not over +35℃.

      Altitude not exceeding 2000 meters above sea level

      Relative humidity of installation site not over 50% at an ambient temperature of +40℃ yet higher humidity is permissible at lower temperature, e.g. 90% at 20℃, Particular measures should be taken for occasional condensation due to temperature fluctuation.

      Pollution grade: 3

      Ⅲ for primary circuit of circuit breaker is suitable for Electromagnetic environment A. and coils of undervoltage releases and Ⅱ for auxiliary circuits and control circuits

      The circuit breaker is suitable for Electromagnetic environment A. should be installed in places where there is no potential explosion risk nor electric conducting dust, nor metal corrosion and insulation damage situations.

      The circuit breaker is suitable for Electromagnetic environment A. should be installed in places where there is no rain and snow.

      The circuit breaker is suitable for Electromagnetic environment A. is suitable for Electromagnetic environment A.

      Type HSL2-100 HSL2-250 HSL2-400 HSL2-800
      Rated current A 16、20、25、32、40、50、63、80、100 100、125、160、180、200、225、250 225、250、315、350、400 400、500、630
      Breaking grade / M / M / M / M
      Pole number 3/4
      Rated insulation voltage V 800
      Rated impulse withstand voltage V 8000
      Rated voltage 400
      Rated limited short circuit breaking capacity kA AC400V 35 50 35 50 50 65 50 65
      Rated service short circuit breaking capacity kA AC400V 18 35 18 35 35 50 35 50
      Residual current protection Non-Adjustable Action current 100mA/200mA/300mA 100mA/300mA/500mA
      Action time 0.1S/0.2S/0.3S 0.2S/0.4S/0.6S
      Non-Adjustable Action current 100mA-200mA-300mA 100mA-300mA-500mA
      Action time 0.1S-0.2S-0.3S 0.2S-0.4S-0.6S
      Operating performance(life) times load 1500 1000 1000 1000
      Without load 8500 700 4000 4000
      boundary dimension(Wide* high*deep) three-pole 92×150×89 107×165×88.5 154×257×106.5 210×281×113
      four-pole 122×150×89 142×165×88.5 198×257×106.5 280×281×113

      Related Products

      HSM9 series miniature circuit breaker
      HSM9 series miniature circuit breaker include HSM9-125, HSM9-63, HSM9N-40 HSM9Z-63 and so on,Miniature circuit breaker is suitable for isolation, control, overload and short circuit protection of terminal distribution lines for…
      More
      Power system switching device (type S)
      Power system conversion device (S) is to realize the two into line, one female united power conversion system between the device and its the executing circuit breaker, mechanical interlocking, controllers…
      More
      HSY1 series digital electric measuring instrument
      HSY1 series digital electric measuring instrument is used for on-line monitoring of various electrical parameters with measurement and display of voltage, current, active power, reactive power, power factor, frequency, electric…
      More
      High breaking capacity、 Intelligent、Small volume、complete functions
      HSW6 Series Intelligent Type Air circuit breaker
      Circuit Breaker with four sections of the full intelligent protection, high breaking capacity, accessories fully functional.
      More
      • HangShen mobile website Latest news on mobile phone
      • HangShen wechat Scan with Wechat app
      • Products
        • Low-voltage distribution
        • Medium voltage distribution
        • Industrial control and protection
        • New energy
        • Complete sets of equipment
      • Download
        • Product sample
        • Manual of the modeling
        • Instruction book
        • Communication protocol
      • About Us
        • Brief introduction
        • “Hangshen” image
        • Technological innovation
        • Technical quality
        • Enterprise reputations
        • Enterprise culture
      • Contact Us
      Copyright 2016© HangShen Electric All Rights Reserved. ICP14040535-3
      Web Development by Anttoweb Web Design.
      WordPress Image Lightbox Plugin
      av大片_伊人网站_无码乱伦_一级爱爱片