<del id="qsc8u"><kbd id="qsc8u"></kbd></del>
    <dfn id="qsc8u"></dfn>
  • <table id="qsc8u"></table>
    <center id="qsc8u"></center>
    • <kbd id="qsc8u"><optgroup id="qsc8u"></optgroup></kbd>
      • Emailhsdq@188.com
      • Phone0571-82699352
      • 中文
      Menu
      • Home
      • Products
        • Low-voltage distribution
        • Medium voltage distribution
        • Industrial control and protection
        • New energy
        • Complete sets of equipment
      • Download
        • Product sample
        • Manual of the modeling
        • Instruction book
        • Communication protocol
      • About Us
        • Brief introduction
        • “Hangshen” image
        • Technological innovation
        • Technical quality
        • Enterprise reputations
        • Enterprise culture
      • Contact Us

      Products

      Home>>HSM6 Series Moulded Case Circuit Breaker
      • New energy
      • Complete sets of equipment
        • Low Voltage Complete-set Switchgear Equipment
        • High Voltage Complete-set Switchgear Equipment
        • Prefabricated substation
      • Low-voltage distribution
        • End Terminal Appliances
        • surge protector
        • automatic transfer switch automatic switch
        • Intelligent instrument
        • Intelligent Type Air Circuit Breaker
        • Moulded Case Circuit Breaker
          • Thermal Magnetic Moulded Case Circuit Breaker
          • Intelligent Type Moulded Case Circuit Breaker
          • Residual Current Circuit Breaker
        • Switch Disconnector
      • Medium voltage distribution
        • Vacuum circuit breaker
      • Industrial control and protection
        • series thermal overload Relay
        • AC contactor
        • motor protector
        • control and protection switch
      • Email hsdq@188.com
        • Technical 0571-82699110
        • Sales 0571-82699109
        • Service 0571-82600655

      HSM6 Series Moulded Case Circuit Breaker

      Description

      HSM6 series moulded case circuit breaker is competently applied in AC 50Hz electrical circuit with rated insulation voltage 800V, rated voltage up to 690V and rated current 10A~ 800A for power distribution against damage due to overload, under voltage, short circuit, in normal conditions, such MCCB may used for infrequent Closing and opening. Those with rated current up to 400A may be used as a protective apparatus for squirrel-cage motors with infrequent start, breaking during operation as well as the motor overload、short circuit and under voltage.

      DownloadHSM6 Series Moulded Case Circuit Breaker
      Tags
      • Low voltage distribution
      • Product Detail
      • Parameters

      The series circuit breakers possesses five rated frames: 63A、100A、250A、400A、800A, the current specification 10 A ~ 800A.

      • limited short circuit breaking capacity can be divided into S type (Typical), M type (Middle and high breaking type), H type (High breaking type), L type (current limiting type);
      • All series circuit breaker can be installed horizontally (lateral), vertical (vertical) and horizontal installation;
      • Whole series of breaker with isolation function
      • The circuit breaker meet the use requirements of installation site with the altitude not exceeding 4000 meters above sea level (need correcting when the altitude above 2000 meters).
      • Humid type circuit breaker can meet the requirements of humid tropics.
      • The breaker can be divided into Electricity and motor protection by purpose.
      • Configurable overload alarm non tripping function
      • Humid type circuit breaker can affected by damp and hot, salt fog, fog bacteria.
      • Working conditions

      The surrounding medium temperature ranging from -5℃ to +40℃, average value within 24 hours not over +35℃.

      Altitude not exceeding 4000 meters above sea level (need correcting when the altitude above 2000 meters).

      Relative humidity of installation site not over 50% at an ambient temperature of +40℃ yet higher humidity is permissible at lower temperature, e.g. 90% at 20℃(humid type circuit breaker at 25℃ is 95%), Particular measures should be taken for occasional condensation due to temperature fluctuation.

      Pollution grade: 3

      Ⅲ for primary circuit of MCCB and coils of undervoltage releases and Ⅱ for auxiliary circuits and control circuits.

      Humid type circuit breaker can affected by damp and hot, salt fog, fog bacteria.

      The MCCB should be installed in places where there is no potential explosion risk nor electric conducting dust, nor metal corrosion and insulation damage situations.

      The MCCB should be installed in places where there is no rain and snow.

      Type HSM6-63 HSM6-100 HSM6-250 HSM6-400 HSM6-800
      Breaking grade S M S M H L S M H L S M H L S M H L
      Rated current A 10/16/20/25/32

      /40/50/63

      16/20/25/32/40/50/63

      /80/100/125

      100/125/160/180/200

      /225/250

      225/250/315/350

      /400

      400/500/630/700/800
      Pole number 3/4
      Rated insulation voltage V 800
      Rated impulse withstand voltage V 8000
      Rated voltage 400、690
      Flashover distance <50 <50(0)
      Rated limited short circuit breaking capacity kA AC400V 35 50 35 50 70 100 35 50 70 100 35 50 70 100 35 65 75 100
      AC690V / / / / 20 / / / 20 / / / 20 / / / 30 /
      Rated service short circuit breaking capacity kA AC400V 35 35 35 50 70 70 35 50 70 70 35 50 70 75 35 65 75 75
      AC690V / / / / 10 / / / 10 / / / 15 / / / 20 /
      Operating performance(life) times load 8000 8000 8000 7500 7500
      Without load 20000 20000 20000 10000 10000
      boundary dimension(Wide* high*deep) three-pole 75×130×61 92×150×85 107×165×102 150×258×107 210×280×115
      four-pole 100×130×61 122×150×85 142×165×102 198×258×107 280×280×115

      Related Products

      HSM9 series miniature circuit breaker
      HSM9 series miniature circuit breaker include HSM9-125, HSM9-63, HSM9N-40 HSM9Z-63 and so on,Miniature circuit breaker is suitable for isolation, control, overload and short circuit protection of terminal distribution lines for…
      More
      New product
      HSM6E Series Moulded Case Circuit Breaker
      HSM6E series moulded case circuit breaker is competently applied in AC 50Hz electrical circuit with rated insulation voltage 800V, rated voltage up to 690V and rated current 16A~ 800A for…
      More
      HSM9L series residual current operated circuit breaker
      HSM9L series residual current operated circuit breaker includes HSM9L-125, HSM9L-63, HSM9NL-63M, HSM9NL-40, HSM9NL-40Mand so on, which is suitable for the distribution system overload,short circuit and residual current fault protection.
      More
      HSL2 Series Residual Current Circuit Breaker
      HSL2 series Residual Current Circuit Breaker is competently applied in AC 50Hz electrical circuit with rated insulation voltage 690V, rated voltage 400V and rated current 16A~ 630A for electric shock…
      More
      • HangShen mobile website Latest news on mobile phone
      • HangShen wechat Scan with Wechat app
      • Products
        • Low-voltage distribution
        • Medium voltage distribution
        • Industrial control and protection
        • New energy
        • Complete sets of equipment
      • Download
        • Product sample
        • Manual of the modeling
        • Instruction book
        • Communication protocol
      • About Us
        • Brief introduction
        • “Hangshen” image
        • Technological innovation
        • Technical quality
        • Enterprise reputations
        • Enterprise culture
      • Contact Us
      Copyright 2016© HangShen Electric All Rights Reserved. ICP14040535-3
      Web Development by Anttoweb Web Design.
      WordPress Image Lightbox Plugin
      av大片_伊人网站_无码乱伦_一级爱爱片
      <dl id="642uy"><tbody id="642uy"></tbody></dl>
          • <abbr id="642uy"><strong id="642uy"></strong></abbr>
            <table id="642uy"><tbody id="642uy"></tbody></table>